李林福, 黄正勇, 左天明. ICP-MS快速测定地质样品中的铀、钍、钨、钼[J]. 内江师范学院学报, 2014, (8). DOI:10.13603/j.cnki.51-1621/z.2014.08.009
引用本文: 李林福, 黄正勇, 左天明. ICP-MS快速测定地质样品中的铀、钍、钨、钼[J]. 内江师范学院学报, 2014, (8).DOI:10.13603/j.cnki.51-1621/z.2014.08.009
LI Lin-fu, HUANG Zheng-yong, ZUO Tian-ming. Rapid Determination of U, Th, W and Mo in Geological Samples by ICP-MS[J]. Journal of Neijiang Normal University, 2014, (8). DOI:10.13603/j.cnki.51-1621/z.2014.08.009
Citation: LI Lin-fu, HUANG Zheng-yong, ZUO Tian-ming. Rapid Determination of U, Th, W and Mo in Geological Samples by ICP-MS[J].Journal of Neijiang Normal University, 2014, (8).DOI:10.13603/j.cnki.51-1621/z.2014.08.009

ICP-MS快速测定地质样品中的铀、钍、钨、钼

Rapid Determination of U, Th, W and Mo in Geological Samples by ICP-MS

  • 摘要:建立一种使用电感耦合等离子体质谱仪快速测定地质样品中的铀、钍、钨、钼元素的方法.实验表明铀、钍、钨、钼检出限分别为:0.03,0.02,0.05,0.03 μg/g.四种元素相对标准偏差均小于10%,测定值均与推荐值吻合.该法适于大批量地质样品中铀、钍、钨、钼同时快速测定.

    Abstract:The experiment is to find out a method for the rapid determination of U, Th, W and Mo in geological samples by ICP-MS. The findings show that the detection limits are respectively 0.03μg/g, 0.02μg/g, 0.05μg/g, and 0.03μg/g. The relative standard deviation of the four elements is all below 10%. The measured results are consistent with the recommended results. Hence, this method is suitable for rapid determination of U, Th, W and Mo of geological samples in large quantities.

/

    返回文章